Methylene blue fluorescence: a new way to protect the ureters?
Editorial

Methylene blue fluorescence: a new way to protect the ureters?

Jonathan Douissard, Nicolas C. Buchs, Jeremy Meyer, Emilie Liot, Frederic Ris

Visceral Surgery Department, University Hospital of Geneva, Geneva, Switzerland

Correspondence to: Jonathan Douissard. Visceral Surgery Department, University Hospital of Geneva and Medical School, Rue Gabrielle-Perret-Gentil 4, 1205 Geneva, Switzerland. Email: jonathan.Douissard@hcuge.ch.

Comment on: Barnes TG, Hompes R, Birks J, et al. Methylene blue fluorescence of the ureter during colorectal surgery. Surg Endosc 2018;32:4036-43.


Received: 30 August 2018; Accepted: 16 September 2018; Published: 18 September 2018.

doi: 10.21037/ales.2018.09.05


Iatrogenic ureteral injury during colorectal surgery is a rare complication, with described rates between 0.15% and 1.9% (1,2). It is however associated with considerable mortality, morbidity and medico-legal issues. Strategies to prevent such injury are diverse but none succeeded to significantly reduce its frequency (3). Identifying ureter in surrounding tissue may be difficult, especially in conditions such as obesity, adhesions, inflammatory status or anatomic variations. Ureter stenting is routinely used in such situation, but has never proved to be efficient and is associated with its own morbidity and increased operative time. Recent development of fluorescence based augmented reality techniques to improve visualization of important structures may provide an elegant answer to this problematic. As such, ureter fluorescence after methylene blue (MB) intravenous injection has been described as feasible in few clinical studies, although results are still heterogeneous (4,5).

In this open label prospective study, Barnes et al. investigated performances of a new dedicated device (PINPOINT Deep Red, NOVADAQ, USA) to identify ureters during colorectal procedures after MB injection. Forty-two patients undergoing colorectal surgery received intravenous MB injection at doses between 0.25 and 1 mg/kg, 10 to 15 minutes before approaching estimated ureter region during dissection. Ureter was then searched both under standard white light and fluorescent light. Two patients were excluded from analysis. In total, 69 ureters were searched in 40 patients. Sixty-four were visible under fluorescent light, the 5 remaining being neither found under white light. Fourteen ureters (20%) could only be identified in fluorescent mode. Subjective assessment considered MB fluorescence useful in 13 cases, showing ureter at an unexpected place in 10 cases, and substantially modifying operative strategy in 2 cases. Optimal dose of MB was estimated at 0.75 mg/kg, and peak of ureter identification probability was obtained at 58 min after injection. No adverse event occurred.

Since it was first described in human by Verbeek et al. (6), MB fluorescence has been investigated in few studies (4,5). Main limitation of this technology to date was low intensity of fluorescent emission by this fluorophore. Thus, new devices improving stimulation intensity and detectors sensitivity were needed. Excellent results from Barnes et al. show that such technology is now available. Noticeably, 20% of ureters identified under fluorescence could not be seen under white light, and in 10 cases ureter was not found where it was expected to. Even though these ureters would not necessarily have been damaged, fluorescence did undoubtedly help at least to reduce operative time and surgeon’s stress. It is important as well to have a precise idea of the concentration needed to have a proper signal according to an optimal dose. Thus, allowing to standardize a technique for the future studies.

Subjective appreciation is a very important parameter when it comes to augmented reality techniques. However, a proper quantification is not yet available and will need to be addressed in future studies.

Events such as iatrogenic ureter injuries or anastomotic leak have become, hopefully, so rare that statistically improving them tends to be difficult. Alternatively, parameters such as attitude change, operative time and surgeon’s general appreciation could be good indicators of usefulness (7). The present study can thus, in our opinion, be considered as proof of concept of this technology as well as a proof of safety.

Overall, this study adds some more evidence that future improvements in minimally invasive surgery will benefit greatly from fluorescence based augmented reality technologies.


Acknowledgments

Funding: None.


Footnote

Provenance and Peer Review: This article was commissioned by the editorial office, Annals of Laparoscopic and Endoscopic Surgery. The article did not undergo external peer review.

Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at http://dx.doi.org/10.21037/ales.2018.09.05). The authors have no conflicts of interest to declare.

Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.


References

  1. Palaniappa NC, Telem DA, Ranasinghe NE, et al. Incidence of iatrogenic ureteral injury after laparoscopic colectomy. Arch Surg 2012;147:267-71. [Crossref] [PubMed]
  2. Kutiyanawala Scott. Jameson. Ureteric injuries during colorectal surgery: strategies for prevention. Colorectal Dis 1999;1:334-7. [Crossref] [PubMed]
  3. Douissard J, Ris F, Morel P, et al. Current Strategies to Prevent Iatrogenic Ureteral Injury During Colorectal Surgery. Surg Technol Int 2018;32:119-24. [PubMed]
  4. Al-Taher M, van den Bos J, Schols RM, et al. Fluorescence Ureteral Visualization in Human Laparoscopic Colorectal Surgery Using Methylene Blue. J Laparoendosc Adv Surg Tech A 2016;26:870-5. [Crossref] [PubMed]
  5. Yeung TM, Volpi D, Tullis ID, et al. Identifying Ureters In Situ Under Fluorescence During Laparoscopic and Open Colorectal Surgery. Ann Surg 2016;263:e1-2. [Crossref] [PubMed]
  6. Verbeek FP, van der Vorst JR, Schaafsma BE, et al. Intraoperative near infrared fluorescence guided identification of the ureters using low dose methylene blue: a first in human experience. J Urol 2013;190:574-9. [Crossref] [PubMed]
  7. Ris F, Liot E, Buchs NC, et al. Multicentre phase II trial of near-infrared imaging in elective colorectal surgery. Br J Surg 2018;105:1359-67. [Crossref] [PubMed]
doi: 10.21037/ales.2018.09.05
Cite this article as: Douissard J, Buchs NC, Meyer J, Liot E, Ris F. Methylene blue fluorescence: a new way to protect the ureters? Ann Laparosc Endosc Surg 2018;3:75.

Download Citation